EMAIL

| CO2 Sensor CM1106-C | |
|---|---|
| Flow Range (m³/h) | DN100: 6~600; DN150: 13~1300; DN200: 20~2000; DN250: 30~3000; DN300: 40~4000 |
| Accuracy | Class 1.0 |
| Boundary Flow (m³/h) | DN100: Qt = 60; DN150: Qt =130; DN200: Qt =200; DN250: Qt =300; DN300: Qt =400 |
| Q Start (m³/h) | DN100: 2; DN150: 4.4; DN200: 6.7; DN250: 10; DN300: 13.4 |
| Maximum Permissible Error | Qmin < Q <Qt, error: ± 2.0%; Qt < Q< Qmax, error: ±1.0% |
| Repeatability | Qmin < Q <Qt, error:≤0.4%; Qt < Q< Qmax, error:≤0.2% |
| Flow Medium | Single-phase gas: natural gas, liquefied petroleum gas, air, etc. |
| Medium Temperature | (-40~60) ℃ |
| Nominal Pressure | ≤1.6MPa |
| Work Pressure | ≤0.8MPa |
| Ambient Temperature | (-40~60) ℃ |
| Storage Temperature | (-40~60) ℃ |
| Transducers Material | Titanium Alloy |
| Power Supply | External power 9~24VDC, built-in lithium battery 3.6V |
| Battery Life | ≥4 years @ RT 20℃ |
| Analog Outputs | 4~20mA |
| Communication Interface | 1x RS485 Port |
| Communication Protocol | Modbus RTU |
| Wireless Communication | GPRS |
| LCD | Accumulated total volume (standard condition), instantaneous flow rate under standard condition, instantaneous flow rate under working condition, temperature, pressure, battery power, etc. condition, temperature, pressure, battery power, etc. |
| Material in Contact with Medium | Stainless Steel 304 |
| Installation Method | PN16 Flange |
| Ingress Protection | IP66 |
| Explosion Proof | Ex db ia IIB T3 Gb |
You can contact Cubic by telephone or email, or you can submit an online Request for Quotation Form.
For Sales: sales@
For Administration: info@hpkmalatang.com