EMAIL

| CO2 Sensor CM1106-C | |
|---|---|
| Measurement range | 400-5000ppm |
| Response time | ≤30s |
| Accuracy | ±(50ppm+3% of reading) @0℃~50℃, 50±10%RH (Note 1 and 2) |
| Working temperature | -10℃~50℃ |
| Working humidity | 0~95%RH(non-condensing)) |
| Power supply | DC 4.5V-5.5V |
| Ripple wave | <50mV |
| Working current | <35mA |
| Signal output | UART_TTL, I²C ,PWM |
| Dimensions | 33x19.7x8.9mm (pin is not included) |
| Weight | 5g |
| Life span | ≥10 years |
Note 1: In normal IAQ applications, accuracy is defined after minimum three (3) ABC periods of continuous operation with ABC on. Some industrial applications do require maintenance. Contact Cubic for further information.
Note 2: Specification is referenced to certified calibration mixtures. Uncertainty of calibration gas mixtures (±2% currently) is to be added to the specified accuracy for absolute measurement.





You can contact Cubic by telephone or email, or you can submit an online Request for Quotation Form.
For Sales: sales@
For Administration: info@hpkmalatang.com