EMAIL

| CO2 Sensor CM1106-C | |
|---|---|
| Measured particle size | 0.3μm~10μm |
| Measurement range | 0~5000μg/m³ |
| Accuracy | PM1.0/PM2.5: 0~35μg/m³ : ±5μg/m³ , 35ug/m³~500μg/m³ : ±15% of reading PM10: 0~100μg/m³ : ±25μg/m³ ,101~500μg/m³: ±25% of reading (GRIMM, 25±2℃, 50 ±10%RH) |
| Reference instrument | GRIMM |
| Dust Source | Cigarette +Arizona A1 |
| Time to first reading | ≤8s |
| Response time | 1s |
| Working humidity | 0~95%RH(non-condensing) |
| Working temperature | -10℃~60℃ |
| Working humidity | 0~95%RH(non-condensing) |
| Ripple wave | <50mV |
| Power supply | DC5V±0.1V |
| Working current | ≤100mA(Working), ≤200uA(Standby) |
| Signal output | UART_TTL, I²C,PWM(customized) |
| Dimensions | W48*H40*D12mm |





You can contact Cubic by telephone or email, or you can submit an online Request for Quotation Form.
For Sales: sales@
For Administration: info@hpkmalatang.com