• Contact
    fix6.png
    Home > Product > Particulate Matter Sensor
    PM3006S.png

    Outdoor Laser Particulate Sensor Module with Sampling Fan PM3006SPM3006S

    Outdoor particulate sensor PM3006S is a linear light source-based particle sensor module with laser scattering technology. It is designed to measure the quantity per unit volume of different particle size and can output particle mass concentration PM1.0, PM2.5, PM10 and TSP in μg/m³ at the same time via mathematical algorithm and scientific calibration. Built-in Cubic auto particle identification technology for accurate measurement in different dust source for ambient air quality.
    Show More

    Features

    • 4 channels concentration output PM1.0, PM2.5, PM10 and TSP in μg/m³
    • High power industrial grade linear laser, accurate identification
    • Vehicle-grade constant current sampling structure fan, ensure constant stable sampling flow
    • Cubic API technology for intelligent dust source identification
    • Wide working temperature -30℃~70℃, suitable for outdoor working environment
    • With voltage regulator design and EMC compatibility, strong antistatic ability.

    Specifications

    CO2 Sensor CM1106-C
    Operating principle Laser scattering
    Measurement range 0~30,000μg/m³
    Output channels PM2.5, PM10 and TSP
    Accuracy PM1.0/PM2.5:<50ug/m³: ±5μg/m³;50~1000μg/m³: ±10%
    PM10: ≤100μg/m³: ±15μg/m³, 100~1000μg/m³: ±15%Reading
    TSP (Note 1): ≤100μg/m³: ±20μg/m³, 100~1000μg/m³: ±20%Reading
    Condition: -30℃~70℃, 50±10%RH, calibration instrument: Grimm
    Data refresh time 1 second
    Time to first reading ≤ 8 Second
    Working condition -30°C ~ 70°C,0-95%RH (non-condensing)
    Storage condition -40°C ~ 85°C, 0-95%RH (non-condensing)
    Power supply DC 5V±0.1V, ripple wave < 50mV
    Working current < 250mA
    Standby current < 25mA
    Dimensions W85*H74*D24.9 mm
    Digital output 1 (default) UART_TTL/I²C(3.3V/5V)
    Life span >5 years (continuous working)
    Note 1: Use the traceability system for benchmarking with Wuhan Station. If there is measurement data discrepancy in other regions, need to do the coefficients correction according to the local dust particle distribution.