EMAIL

| CO2 Sensor CM1106-C | |
|---|---|
| Operating principle | Laser scattering |
| Measured particle size | 0.3μm~10μm |
| Measurement range | 0~1000μg/m³ |
| Resolution | 1μg/m³ |
| Working condition | -10°C ~ 60°C, 0-95%RH (non-condensing) |
| Storage condition | -40°C ~ 80°C, 0-95%RH (non-condensing) |
| Measurement accuracy for PM1.0&PM2.5 | 0 ~100μg/m³, ±10μg/m³ >100μg/m³, ±10% of reading Condition: 25±2℃, 50±10%RH, Reference instrument: GRIMM, Dust source: Cigarette |
| Measurement accuracy for PM10 | 0 ~100μg/m³, ±30μg/m³ 101 ~1000μg/m³, ±30% of reading Condition: 25±2℃, 50±10%RH, Reference instrument: GRIMM Dust source: Cigarette |
| Response time | 1 sec |
| First time to reliable reading | 4 sec |
| Power supply | DC 5V±0.1V Ripple wave<50 mV |
| Working current | <53 mA |
| Standby current | <5 mA |
| Dimensions | 42×35×23.7 mm |
| Digital output 1 (default) | UART_TTL_3.3V(default) I²C_3.3V/5V(default) |
| Digital output 2 | PWM (customized) |
| Output method | Default by active output after powering on, sampling time interval should be over 1,000 ms |
| MTTF | 37,297 hrs (continuous turn on) |



You can contact Cubic by telephone or email, or you can submit an online Request for Quotation Form.
For Sales: sales@
For Administration: info@hpkmalatang.com