EMAIL

| CO2 Sensor CM1106-C | |
|---|---|
| Measurement | CO2,CO,HC,O2,NO gases, Lambda display |
| Technology | CO2,CO,HC(NDIR),O2,NO(ECD) |
| Resolution | CO2:0.01%; CO:0.01%; HC:1ppm; O2:0.01%; NO:1ppm |
| Relative error | CO2: ±4%; CO: ±3%; HC: ±5%; O2:±3%; NO: ±5% |
| Absolute error | CO2: ±0.4%; CO: ±0.06%; HC: ±12ppm; O2:±0.1%; NO: ±25ppm |
| Warm-up time | 10 minutes |
| Display | LCD display |
| Response time | TD+T90:10 second(NDIR),ECD:30 seconds |
| Power | 110V-220V±10% 50Hz±1Hz |
| Operation temperature | 0℃ to 40℃ |
| Dimension | 260mm*180mm*360mm |
| Net weight | 6kg |
| Flow rate | 0.7-1.2L/min |
| Standard accessories | Sampling pipe, sampling probe,RS-232 cable, standby filters, PC software |
| Options | Oil temperature option,inbult printer,RPM sensor options |
You can contact Cubic by telephone or email, or you can submit an online Request for Quotation Form.
For Sales: sales@
For Administration: info@hpkmalatang.com